pilot plant for co2 removal process
The pilot plant for CO2 removal based on patents WO 2011/138425 A1 and WO 2013/072257 A1 mainly consists of following parts:
- Raw gas inlet.
Can be used with gas temperatures up to well above 100°C.
- A fabric filter is installed before the first reactor and retains dust particles in the off-gas.
- One adsorber reactor
- The quench is followed by a demister.
- One adsorber reactor
- One water tap connected with an ordinary flexible tube for fresh water supply (1 bar pressure gauge) as well as a sprinkling pump.
- One buffer tank for the produced nitric or sulfuric acid
- One blower
- The clean gas is released into the environment by a vertically positioned duct next to the plant.
- Measuring devices (inlet/outlet) for NOx, SO2, CO, CO2, dust, as well as temperature, pressure, pressure difference, flow rate, and acid concentration
- Electric control cabinet for control, operation and monitoring instruments